Medidores de LCR-ESR (Inductancia, Capacitancia y Resistencia) Hioki

Hioki IM3533-01

Medidor LCR de banco 100 MΩ

Nuevo
Garantia | 3 Años
No Disponible
Temporalmente

¿Dudas?

Descripción
Medidor LCR de banco, impedancia máxima 100 MΩ; equipo con precisión de ± 0.05%, 10 rangos. Comunicación: USB; display color TFT. Este modelo tiene la función de barrido. Modelo Hioki IM3533-01
código: IM3533-01
Características
Medidor LCR de banco 100 MΩ - Hioki IM3533-01
  • » ± 0.05% accuracy with wide measurement range (DC, 40Hz to 200kHz, 5mV to 5V, 10uA to 50mA)
  • » Non-stop testing over mixed measurement conditions such as C-D and ESR at 10 times the speed of previous models
  • » Built-in low impedance high precision mode effective for testing low inductance or the ESR of aluminum electrolysis capacitance (10x the measurement speed and dramatic improvements in repeatability and stability over the previous model 3522-50)
  • » Dedicated modes for measuring transformer winding ratio, mutual inductance and temperature compensated DCR
  • » Frequency sweep testing
  • » 2m/4m cable setting in addition to the standard 0m/1m
  • » This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. All probes are constructed with a 1.5D-2V coaxial cable. For an RS-232C connection: A crossover cable for interconnection can be used You can use the RS-232C CABLE 9637 without hardware flow control.
  • » Measurement modes: LCR, Transformer testing (N, M, ΔL), Analyzer (sweep testing), Continuous Testing (LCR/ Analyzer mode)
  • » Measurement parameters: Z, Y, θ, Rs (ESR), Rp, DCR (DC resistance), X, G, B, Cs, Cp, Ls, Lp, D (tanδ), Q, N, M, ΔL, T
  • » Measurement range: 100mΩ to 100MΩ, 10 ranges (All parameters defined in terms of Z )
  • » Displayable range: Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp : ± (0.000000 [unit] to 9.999999G [unit]) Real value display for Z and Y only; θ: ± (0.000° to 999.999°), D: ± (0.000000 to 9.999999); Q: ± (0.00 to 99999.99), ?%: ± (0.0000% to 999.9999%)
  • » Basic accuracy: Z : ±0.05%rdg. θ: ±0.03°
  • » Measurement frequency: 1mHz to 200kHz (1mHz to 10Hz steps)
  • » Measurement signal level: [Normal mode] V mode, CV mode: 5 mV to 5 Vrms, 1 mVrms steps CC mode: 10 µA to 50 mArms, 10 µArms steps [Low impedance high accuracy mode] V mode, CV mode: 5 mV to 2.5 Vrms, 1 mVrms step CC mode: 10 µA to 100 mArms, 10 µArms steps
  • » Output impedance: Normal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω
  • » Display: 5.7-inch touch-screen color TFT, display can be set to ON/OFF
  • » Measurement time: 2 ms (1 kHz, FAST, display OFF, representative value)
  • » Functions: DC bias measurement, DC resistance temperature compensation (converted reference temperature display), Comparator, BIN measurement (classify function), Panel loading/saving, Memory function
  • » Interface: EXT I/O (Handler), USB communication (high-speed), USB memory Optional: Choose 1 from RS-232C, GP-IB, or LAN
  • » Power supply: 100 to 240 V AC, 50/60 Hz, 50 VA max
Qué Incluye:
  • Power cord × 1
  • Instruction Manual × 1
  • CD-R (Includes PC commands and sample software) × 1

Accesorios opcionales para Hioki IM3533-01




Hioki
IM9110
SMD Test Fixture for Hioki LCR IM3500 Series Methers
US$
$ ------

Ver más Medidores de LCR-ESR (Inductancia, Capacitancia y Resistencia)

Hacienda la Muralla #136, CP. 76180
Jardines de la Hacienda. Querétaro, México.
®️ CEDE 2024  |  Actualizado: 2024-04-19 |  www.cedesa.com.mx
(+52) 442 212 20 12
• Precios en Dólares Americanos (USD) sujetos al tipo de cambio publicado en cedesa.com.mx/tc el día de pago . No incluyen el 16% de Impuesto al Valor Agregado (IVA).
• Aunque el contenido de este sitio web ha sido cuidadosamente revisado y actualizado, las especificaciones, disponibilidad de productos y precios aquí mostrados pueden cambiar sin previo aviso.
• Todas las marcas, fotografías y diseños son propiedad de sus respectivos autores.
• Estamos comprometidos con el uso responsable de la información, consulte nuestra Política de Privacidad.
Si tiene algún comentario acerca de este sitio y su contenido comuníquese con nuestro departamento de desarrollo web.
• (*)La disponibilidad es salvo previa venta. Favor de confirmar existencias y tiempos de entrega.
• Todos los certificados de calibración incluidos de fábrica en los equipos que así lo indiquen tienen como finalidad mostrar que el equipo está dentro de los parámetros de medida especificados, no son un servició de certificación “en si”.
Al momento de ser surtido un instrumento que incluye certificado de calibración de fábrica estos certificados pueden tener menos de un año de vigencia o incluso estar caducos debido a los tiempos de almacenamiento y distribución. Esto no demerita el objetivo original para lo que el documento fue incluido en el equipo ni obliga a los fabricantes o al distribuidor a suministrar un nuevo certificado en caso de que el incluido en el equipo surtido este caduco.
Si requiere certificados con vigencia de un año, con datos de los parámetros calibrados y emitidos con información personalizada de su empresa, así como con trazabilidad a patrones nacionales del CENAM (México) y acreditación EMA, debe solicitarlos como un servicio con costo y por separado.